Advantages of the Chainflex® special cable:

Chainflex® special cables for Energy Chains® are cables for bending radii from 12,5xd. The data cables are tested in E-Chains® with many million cycles. There are gradient fiber glass cables, CAT5 cables and Profibus cables to choose from. The Chainflex® special cable has various approvals and compliances: UL, CSA, CE Desina. This highly flexible cable is designed for high stressing and is also available as a flame-retardant and oil-resistant cable. The Chainflex® special cable is also halogen-free and flexible at low temperatures.

Chainflex® Network/ Ethernet-/LWL-/Fieldbus-cables

CFLG.6G gradient glass-fiber cable

Chainflex® CFLG.6G gradient glass-fiber cable  

Gradient glass-fiber cable for heavy duty use

Halogen-free

low-temperature-flexible up to -40 °C

Outer jacket on TPE base

Minimum bending radius: 15 x cable diameter

CFLG.12G gradient glass-fiber cable

Chainflex® CFLG.12G gradient glass-fiber cable  

Gradient glass-fiber cable for heavy duty use

Halogen-free

low-temperature-flexible up to -40 °C

Outer jacket on TPE base

Minimum bending radius: 15 x cable diameter

CAT5 Ethernet special cable TPE

Chainflex® CAT5 Ethernet special cable  

CAT5 cable

Resistant to oil, organic oil

Nominal voltage: 30 V.

External jacket on the basis of TPE

Minimum bending radius: 12,5 x cable diameter

CAT5 Ethernet special cable PVC

Chainflex® CAT5 Ethernet special cable  

CAT5 cable

Oil-resistant

Nominal voltage: 30 V.

Outer jacket on PVC base

Minimum bending radius: 12,5 x cable diameter

CAT5 Ethernet bus cable, PVC, flame-retardant

chainflex® CAT5 Ethernet bus cable  

CAT5 cable

Oil-resistant

flame-retardant

Nominal voltage: 50 V

Outer jacket on PVC base

Minimum bending radius: 15 x cable diameter

CAT5 Ethernet special cable PUR

Chainflex® CAT5 Ethernet special cable  

CAT5 cable

Resistant to oils and coolants

Halogen-free

flame-retardant

External jacket on the basis of PUR

Minimum bending radius: 12,5 x cable diameter

CAT5 Ethernet bus cable, iguPUR

chainflex® CAT5 iguPUR Ethernet bus cable  

CAT5 cable

Jacket based on iguPUR

Overall Shield

Oil-resistant

flame-retardant

Minimum bending radius: 15 x cable diameter

CAT5 Ethernet special cable PUR, torsionable

Chainflex® CAT5 Ethernet special cable  

CAT5 cable

Oil-resistant

UV-resistant

Torsion-resistant, tin-plated braided copper shield

External jacket on the basis of PUR

Minimum bending radius: 10 x cable diameter

CAT5 Ethernet special cable PUR-SPECIAL

chainflex® CAT5 Ethernet special cable, PUR-SPECIAL  

CAT5 cable

Oil-resistant

UV-resistant

External jacket on the basis of PUR

Minimum bending radius: 10 x cable diameter

CAT5 Ethernet special cable L/T angle TPE

Chainflex® CAT5 Ethernet special cable L/T angle  

CAT5 cable

Resistant to oil, organic oil

Nominal voltage: 30 V.

External jacket on the basis of TPE

Minimum bending radius: 12,5 x cable diameter

CAT5 Ethernet special cable L/T angle PVC

Chainflex® CAT5 Ethernet special cable L/T angle  

CAT5 cable

Oil-resistant

Nominal voltage: 30 V.

Outer jacket on PVC base

Minimum bending radius: 12,5 x cable diameter

CAT5 Ethernet special cable L/T angle PUR

Chainflex® CAT5 Ethernet special cable L/T angle  

CAT5 cable

Resistant to oils and coolants

Halogen-free

flame-retardant

External jacket on the basis of PUR

Minimum bending radius: 12,5 x cable diameter

CAT5 Ethernet special cable L/T angle PUR torsionable

Chainflex® CAT5 Ethernet special cable L/T angle  

CAT5 cable

Oil-resistant

UV-resistant

External jacket on the basis of PUR

Minimum bending radius: 10 x cable diameter

CAT6 Ethernet special cable TPE

Chainflex® CAT6 Ethernet special cable  

CAT6 bus cable

Resistant to oils including organic oils

Overall Shield

flame-retardant

External jacket on the basis of TPE

Hydrolyse- and microben-resistant

Minimum bending radius: 10-12,5 x cable diameter

CAT6 Ethernet bus cable, PVC

chainflex® CAT6 Ethernet bus cable  

CAT6 special cable

Oil-resistant

Outer jacket on PVC base

Overall Shield

flame-retardant

Minimum bending radius: 12,5 x cable diameter

CAT6 Ethernet bus cable, PUR

chainflex® CAT6 Ethernet bus cable  

CAT6 special cable

PUR outer jacket

Overall Shield

Resistant to oils and coolants

notch resistant

PVC- and halogen-free

flame-retardant

Hydrolyse- and microben-resistant

Minimum bending radius: 12,5 x cable diameter

CAT6A Ethernet bus cable, PUR

chainflex® CAT6A Ethernet bus cable  

CAT6 special cable

PUR outer jacket

Overall Shield

Resistant to oils and coolants

notch resistant

PVC- and halogen-free

flame-retardant

Hydrolyse- and microben-resistant

Minimum bending radius: 12,5 x cable diameter

CAT6A Ethernet bus cable, PUR, twistable

chainflex® CAT6A Ethernet bus cable  

CAT6A special cable

PUR outer jacket

Overall Shield

Resistant to oils and coolants

notch resistant

flame-retardant

Hydrolyse- and microben-resistant

Minimum bending radius: 10 x cable diameter

CAT6A Ethernet bus cable, PVC

chainflex® CAT6A Ethernet bus cable  

CAT6A special cable

PVC outer jacket

Overall Shield

Oil-resistant

flame-retardant

Minimum bending radius: 12,5 x cable diameter

CAT6A Ethernet bus cable, TPE

chainflex® CAT6A Ethernet bus cable  

CAT6A special cable

TPE outer jacket

Overall Shield

Resistant to oils including organic oils

flame-retardant

Hydrolyse- and microben-resistant

Minimum bending radius: 10-12,5 x cable diameter

CAT7 Ethernet bus cable TPE

chainflex® CAT7 Ethernet bus cable  

CAT7 special cable

TPE outer jacket

Overall Shield

Resistant to oils including organic oils

flame-retardant

Hydrolyse- and microben-resistant

Minimum bending radius: 10-12,5 x cable diameter

CAT7 Ethernet bus cable, PUR, twistable

chainflex® CAT7 Ethernet bus cable  

CAT7 special cable

For torsionable stressing capacity

PUR outer jacket

Overall Shield

Resistant to oils and coolants

notch resistant

flame-retardant

Hydrolyse- and microben-resistant

Minimum bending radius: 12,5 x cable diameter

Ready harnessed profibus-cable PVC

Chainflex® network technology assembled profibus cables  

Profibus-cables

Oil-resistant

UV-resistant

flame-retardant

Outer jacket on PVC base

Minimum bending radius: 12,5 x cable diameter

Ready harnessed profibus-cables PUR

Chainflex® network technology assembled profibus cables  

Profibus-cables

Resistant to oils and coolants

UV-resistant

flame-retardant

External jacket on the basis of PUR

Minimum bending radius: 12,5 x cable diameter

Ready harnessed profibus-cables TPE

Chainflex® network technology assembled profibus cables  

Profibus-cables

Oil-resistant

UV-resistant

flame-retardant

External jacket on the basis of TPE

Minimum bending radius: 10-12,5 x cable diameter

Assembled Profinet cables PVC

Chainflex® network technology assembled profibus cables  

Profinet cables

Oil-resistant

UV-resistant

flame-retardant

Outer jacket on PVC base

Minimum bending radius: 12,5 x cable diameter

assembled profibus cables PUR

Chainflex® network technology assembled profibus cables  

Profinet cables

Oil-resistant

UV-resistant

flame-retardant

Outer jacket on PUR base

Minimum bending radius: 12,5 x cable diameter

assembled profibus cables TPE

Chainflex® network technology assembled profibus cables  

Profinet cables

Oil-resistant

UV-resistant

flame-retardant

Outer jacket on TPE base

Minimum bending radius: 10-12,5 x cable diameter

Assembled Profinet cables PVC

Chainflex® network technology assembled profibus cables  

Profinet cables

PVC outer jacket

flame-retardant

Overall Shield

Minimum bending radius: 15 x cable diameter

Assembled Profinet cables, PUR, twistable

Chainflex® network technology assembled profibus cables  

Profinet cables

For torsionable stressing capacity

PUR outer jacket

Overall Shield

Resistant to oils and coolants

notch resistant

flame-retardant

Minimum bending radius: 5 x cable diameter

... No minimum order quantity, 1.040 types from stock, no cutting costs* ... (*up to 10 cuts of the same type)

More than 100,000 products available! Delivery and consultation Mon-Fri from 7am-8pm and Sat from 8am-12pm!


Contact
Other contact options

+49 (0) 2203-9649-0
Send e-mail to igus®
igus® contact
Back to the top