Chainflex® special cables for Energy Chains® are cables for bending radii from 12,5xd. The data cables are tested in E-Chains® with many million cycles. There are gradient fiber glass cables, CAT5 cables and Profibus cables to choose from. The Chainflex® special cable has various approvals and compliances: UL, CSA, CE Desina. This highly flexible cable is designed for high stressing and is also available as a flame-retardant and oil-resistant cable. The Chainflex® special cable is also halogen-free and flexible at low temperatures.
Gradient glass-fiber cable for heavy duty use
Halogen-free
low-temperature-flexible up to -40 °C
Outer jacket on TPE base
Minimum bending radius: 15 x cable diameter
Gradient glass-fiber cable for heavy duty use
Halogen-free
low-temperature-flexible up to -40 °C
Outer jacket on TPE base
Minimum bending radius: 15 x cable diameter
CAT5 cable
Resistant to oil, organic oil
Nominal voltage: 30 V.
External jacket on the basis of TPE
Minimum bending radius: 12,5 x cable diameter
CAT5 cable
Oil-resistant
Nominal voltage: 30 V.
Outer jacket on PVC base
Minimum bending radius: 12,5 x cable diameter
CAT5 cable
Oil-resistant
flame-retardant
Nominal voltage: 50 V
Outer jacket on PVC base
Minimum bending radius: 15 x cable diameter
CAT5 cable
Resistant to oils and coolants
Halogen-free
flame-retardant
External jacket on the basis of PUR
Minimum bending radius: 12,5 x cable diameter
CAT5 cable
Jacket based on iguPUR
Overall Shield
Oil-resistant
flame-retardant
Minimum bending radius: 15 x cable diameter
CAT5 cable
Oil-resistant
UV-resistant
Torsion-resistant, tin-plated braided copper shield
External jacket on the basis of PUR
Minimum bending radius: 10 x cable diameter
CAT5 cable
Oil-resistant
UV-resistant
External jacket on the basis of PUR
Minimum bending radius: 10 x cable diameter
CAT5 cable
Resistant to oil, organic oil
Nominal voltage: 30 V.
External jacket on the basis of TPE
Minimum bending radius: 12,5 x cable diameter
CAT5 cable
Oil-resistant
Nominal voltage: 30 V.
Outer jacket on PVC base
Minimum bending radius: 12,5 x cable diameter
CAT5 cable
Resistant to oils and coolants
Halogen-free
flame-retardant
External jacket on the basis of PUR
Minimum bending radius: 12,5 x cable diameter
CAT5 cable
Oil-resistant
UV-resistant
External jacket on the basis of PUR
Minimum bending radius: 10 x cable diameter
CAT6 bus cable
Resistant to oils including organic oils
Overall Shield
flame-retardant
External jacket on the basis of TPE
Hydrolyse- and microben-resistant
Minimum bending radius: 10-12,5 x cable diameter
CAT6 special cable
Oil-resistant
Outer jacket on PVC base
Overall Shield
flame-retardant
Minimum bending radius: 12,5 x cable diameter
CAT6 special cable
PUR outer jacket
Overall Shield
Resistant to oils and coolants
notch resistant
PVC- and halogen-free
flame-retardant
Hydrolyse- and microben-resistant
Minimum bending radius: 12,5 x cable diameter
CAT6 special cable
PUR outer jacket
Overall Shield
Resistant to oils and coolants
notch resistant
PVC- and halogen-free
flame-retardant
Hydrolyse- and microben-resistant
Minimum bending radius: 12,5 x cable diameter
CAT6A special cable
PUR outer jacket
Overall Shield
Resistant to oils and coolants
notch resistant
flame-retardant
Hydrolyse- and microben-resistant
Minimum bending radius: 10 x cable diameter
CAT6A special cable
PVC outer jacket
Overall Shield
Oil-resistant
flame-retardant
Minimum bending radius: 12,5 x cable diameter
CAT6A special cable
TPE outer jacket
Overall Shield
Resistant to oils including organic oils
flame-retardant
Hydrolyse- and microben-resistant
Minimum bending radius: 10-12,5 x cable diameter
CAT7 special cable
TPE outer jacket
Overall Shield
Resistant to oils including organic oils
flame-retardant
Hydrolyse- and microben-resistant
Minimum bending radius: 10-12,5 x cable diameter
CAT7 special cable
For torsionable stressing capacity
PUR outer jacket
Overall Shield
Resistant to oils and coolants
notch resistant
flame-retardant
Hydrolyse- and microben-resistant
Minimum bending radius: 12,5 x cable diameter
Profibus-cables
Oil-resistant
UV-resistant
flame-retardant
Outer jacket on PVC base
Minimum bending radius: 12,5 x cable diameter
Profibus-cables
Resistant to oils and coolants
UV-resistant
flame-retardant
External jacket on the basis of PUR
Minimum bending radius: 12,5 x cable diameter
Profibus-cables
Oil-resistant
UV-resistant
flame-retardant
External jacket on the basis of TPE
Minimum bending radius: 10-12,5 x cable diameter
Profinet cables
Oil-resistant
UV-resistant
flame-retardant
Outer jacket on PVC base
Minimum bending radius: 12,5 x cable diameter
Profinet cables
Oil-resistant
UV-resistant
flame-retardant
Outer jacket on PUR base
Minimum bending radius: 12,5 x cable diameter
Profinet cables
Oil-resistant
UV-resistant
flame-retardant
Outer jacket on TPE base
Minimum bending radius: 10-12,5 x cable diameter
Profinet cables
PVC outer jacket
flame-retardant
Overall Shield
Minimum bending radius: 15 x cable diameter
Profinet cables
For torsionable stressing capacity
PUR outer jacket
Overall Shield
Resistant to oils and coolants
notch resistant
flame-retardant
Minimum bending radius: 5 x cable diameter
... No minimum order quantity, 1.040 types from stock, no cutting costs* ... (*up to 10 cuts of the same type)
More than 100,000 products available! Delivery and consultation Mon-Fri from 7am-8pm and Sat from 8am-12pm!