iglidur® J350 against PPA GF-30 shafts
The iglidur® J350 material was tested for a customer from the automobile industry. In addition to the required temperature and media-resistance, the primary reasons were good wear-resistance against the PPA GF-30 plastic shaft used by the customer.
The igus® test lab conducted a wear test using the customer's original shaft material under the following conditions to explicitly test the good suitability of iglidur® J350:
Load: 16 N
Pivot angle: 20°
Speed: 2 Hz ≙ 0,007 m/s
Temperature: 50% of time 150°C; 30% of time 120°C; 20% of time room temperature
Operating time: > 800.000 cycles ≙about 3 km